BALBOA ERROR CODES

 

Balboa Error Codes

pd = Power supply, unit running on battery backup

OH = sensors reading 112-118 degrees

Flo = Improper flow or pressure Switch

Cool = Water temp 20 degrees below set point

ICE = Potential freeze condition has been detected.

Sn1 = Hi-limit sensor malfunction

Sn3 = Temp sensor malfunction

ILOC = Interlock failure – possible Pump or ozone spike.

malfunction detected

 

HURRICAN ERROR CODES

 

Hurricane Error Codes

PS = Flow or pressure Switch failure

SH = Shorted sensor

OP = Open sensor

LO = Temp below 60 degrees – freeze

HL = Temp above 118 degrees

 

Hercules Error Codes

 

Hercules Error Codes

OH = Spa temp exceeds Acceptable limits

FLO = Flow problem

ICE = Freeze condition detected

SN1 = Hi-limit sensor failure

SN2 = Temp sensor failure

SUNDANCE ERROR CODES

 

Sundance Error Codes

ILOC = Interlock failure

OH = Sensor indicates water temp above

FLO = Pressure Switch malfunction

acceptable limits

Hold = Panel buttons pressed to many time to quickly

HOT = PCB temperature above acceptable limit

ICE = Freeze condition

PnL = Communication between PCB and panel interrupted

Sn1 = Hi-limit sensor malfunction

Sn3 = Temp sensor malfunction ----- = Watch dog – Potential damage to spa

– air blower on equipment

BRETT ERROR CODES

 

Brett Error Codes

OH = temp exceeds 118 degrees

Fr = Freeze condition – temp below 40 degrees

FL = Pressure switch failure

EO = Shorted temp sensor

E1 = Open temp sensor

E2 = Shorted hi-limit sensor

E3 = Open hi-limit sensor

E4 = Shorted flow switch

E7 = Improper electrical connection

GECKO ERROR CODES

 
!

Gecko Error Codes

FLO = Pressure Switch failure, switch open

FLC = Pressure switch failure, switch closed

Prr = Temp sensor failure

Prh = Hi-limit sensor failure

FrE = possible freeze condition detected

VITA ERROR CODES

 
!

Vita Error Codes

HiLi = Water temp over acceptable limit

BJ2P = Pump/Blower purge – Normal condition

FP = Freeze protect – temp under acceptable limit

SS=0; SS=S; LS=O; LS=S = Multiple causes; Open sensors, bad connection to panel, Improper voltage,

etc.